Vista 20p keypads
Vista 20p keypads








vista 20p keypads

Enter 00 if you do not want your system to beep.If you want the system to rapidly beep 10 seconds before it arms, enter 01.Note: You will not need to enter *37 if you have just completed step 6. Step 7: Audible Exit Warning (*37) (-2 in the Installation and Setup Guide)

vista 20p keypads

The system will advance you to the next step when all delay times are entered.

  • Then enter the entry delay time for Entry Delay 2 on Partition 2.
  • Then enter the entry delay time for Entry Delay 2 on Partition 1.
  • Then enter the entry delay time for Entry Delay 1 on Partition 2.
  • Enter the entry delay time for Entry Delay 1 on Partition 1.
  • Note: You will not need to enter *35 if you have just completed step 5.
  • 30 to 90 seconds = enter the desired seconds 30-90.
  • Step 6: Entry Delay (*35) (-2 in the Installation and Setup Guide) As with the exit delay, you must enter an entry delay for both partition 1 and 2 even if only 1 partition will be used. Note: Both partitions must have a delay time programmed, even if you do not have a 2nd partition.Īfter both delay times have been entered the system will automatically take you to step 6.
  • Then repeat the exit delay for Partition 2.
  • Then enter the exit delay time for Partition 1.
  • If the delay time is more than 96 seconds, then enter 97 and then the system will give you a delay of 120 seconds. If the delay is between 45 and 96 seconds, then enter the actual seconds. Step 5: Exit Delay (*34) (-2 in the Installation and Setup Guide)

    vista 20p keypads

    If you would like to change the installer code, press *20 + new installer code.This is for clearing the ID number for Central Station. If you will be using central station monitoring: Press *96 and the system will beep.This will ensure that there is a clean slate to start from. We can begin programming from this point.Field 20 (Installer Code) will be displayed on the screen.Keypads have to be addressed 16 to 23 (no duplicates), but come defaulted at 31 and will not work until they are re-addressed.Īfter the keypad is addressed, you will need to enter programming: On each additional keypad you will need to enter a unique address: 17, 18, etc.ĭo Not Duplicate Keypad Addresses.Con Addr = will appear and you will need to enter 16.Within 30 seconds of the main keypad receiving power: Press and hold the 1 and 3 buttons at the same time.Upon 50 seconds of power up, you will need to press and hold * and # at same time.Įxit Programming=*99 or 00 depending on where you are at Reason: You have to make a programming change to each keypad upon 30 seconds of power being sent to the keypad. NOTE: DO NOT hook power to the keypad until the entire system is installed and ready for programming.

    #VISTA 20P KEYPADS SERIES#

  • Total Connect 2.0 Package Monitoring Add-Onsĭownload the Honeywell Vista Series 15P, 20P and 21ip Quickstart Guide HERE.
  • Central Station Alarm Monitoring Services.